4ALP
The Lin28b Cold shock domain in complex with hexauridine
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY |
Synchrotron site | BESSY |
Beamline | BL14-1 |
Temperature [K] | 100 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 95.982, 61.166, 63.219 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.420 - 1.480 |
R-factor | 0.17023 |
Rwork | 0.169 |
R-free | 0.18768 |
Structure solution method | OTHER |
Starting model (for MR) | NONE |
RMSD bond length | 0.013 |
RMSD bond angle | 1.568 |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 32.400 |
High resolution limit [Å] | 1.480 |
Rmerge | 0.060 |
Number of reflections | 60327 |
<I/σ(I)> | 1 |
Completeness [%] | 96.2 |
Redundancy | 6.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |