Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4AFH

Capitella teleta AChBP in complex with lobeline

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
DetectorADSC QUANTUM 4
Spacegroup nameP 21 21 21
Unit cell lengths78.637, 110.975, 134.071
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.352 - 1.880
R-factor0.172
Rwork0.170
R-free0.21310
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2uz6
RMSD bond length0.009
RMSD bond angle1.161
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX ((PHENIX.REFINE: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.3501.980
High resolution limit [Å]1.8801.880
Rmerge0.0680.528
Number of reflections93581
<I/σ(I)>10.11.4
Completeness [%]97.482.4
Redundancy4.52.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP0.2 M imidazole-malate at pH 5.5, 33% (vol/vol) PEG 600, and (vol/vol) 3% glycerol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon