4ACD
GSK3b in complex with inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | MAX II BEAMLINE I711 |
Synchrotron site | MAX II |
Beamline | I711 |
Temperature [K] | 173 |
Detector technology | CCD |
Detector | BRUKER |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 83.319, 84.989, 177.669 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 21.220 - 2.600 |
R-factor | 0.1803 |
Rwork | 0.178 |
R-free | 0.22630 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.170 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Refinement software | BUSTER (2.11.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 21.000 | 2.740 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.080 | 0.720 |
Number of reflections | 34093 | |
<I/σ(I)> | 19.3 | 2.2 |
Completeness [%] | 87.4 | 88.6 |
Redundancy | 4.5 | 4.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |