3OKU
Human Carbonic Anhydrase II in complex with 2-Ethylestrone-3-O-sulfamate
Experimental procedure
実験手法 | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2010-06-09 |
Detector | RIGAKU RAXIS IV++ |
Spacegroup name | P 1 21 1 |
格子定数 [Å] | 42.168, 41.199, 71.548 |
格子定数 [度] | 90.00, 104.12, 90.00 |
精密化法
残基 | 23.130 - 1.450 |
R因子 | 0.142 |
Rwork | 0.141 |
R-free | 0.15800 |
Structure solution method | MIR |
Starting model (for MR) | 2ili |
結合長の平均二乗偏差(RMSD) [Å] | 0.010 |
結合角の平均二乗偏差(RMSD) [度] | 1.418 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHENIX (1.6.3_467) |
Refinement software | PHENIX (1.6.3_467) |
Quality characteristics
Overall | Outer shell | |
分解能 [Å] (低) | 50.000 | 1.500 |
分解能 [Å] (高) | 1.450 | 1.450 |
Rmerge_l_obs | 0.206 | |
独立反射数 | 40524 | |
<I/σ(I)> | 28.4 | 6 |
完全性 [%] | 95.3 | 80.3 |
冗長性 | 4.7 | 3.5 |
結晶化条件
結晶ID | 方法 | pH | 温度 | 溶液条件 |
1 | 8 | 298 | 1.4 M Sodium citrate, 100mM Tris, 7.5 mM 2-Ethylestrone 3-O-sulfamate, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |