3WUH
Qri7 and AMP complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-5A |
| Synchrotron site | Photon Factory |
| Beamline | BL-5A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-01-19 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 43 3 2 |
| Unit cell lengths | 180.315, 180.315, 180.315 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.010 - 2.937 |
| R-factor | 0.2255 |
| Rwork | 0.223 |
| R-free | 0.27340 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4k25 |
| RMSD bond length | 0.002 |
| RMSD bond angle | 0.667 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.8.3_1479)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.100 |
| High resolution limit [Å] | 2.937 |
| Number of reflections | 22014 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 25% PEG 400, 3% w/v dextran sulfate sodium salt (Mr 5000), 0.1M HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |