3WI0
P453H/I471T mutant of PB2 middle domain from influenza virus A/Puerto Rico/8/34(H1N1)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2013-08-05 |
| Detector | RIGAKU RAXIS VII |
| Wavelength(s) | 1.54 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 107.818, 107.818, 136.615 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 20.975 - 1.998 |
| R-factor | 0.1868 |
| Rwork | 0.182 |
| R-free | 0.22860 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2vqz |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.032 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.980 | 2.090 |
| High resolution limit [Å] | 1.998 | 1.998 |
| Number of reflections | 20909 | |
| Completeness [%] | 99.7 | 96.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 277 | 1.2M NaCl, 2.5% (v/v) ethanol, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K |