3WHD
C-type lectin, human MCL
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL32XU |
Synchrotron site | SPring-8 |
Beamline | BL32XU |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-04-12 |
Wavelength(s) | 1.0 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 85.190, 96.056, 104.826 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.483 - 2.290 |
R-factor | 0.1778 |
Rwork | 0.176 |
R-free | 0.21800 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.171 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 40.483 |
High resolution limit [Å] | 2.290 |
Rmerge | 0.141 |
Number of reflections | 19569 |
<I/σ(I)> | 8.65 |
Completeness [%] | 100.0 |
Redundancy | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |