Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-17A |
| Synchrotron site | Photon Factory |
| Beamline | BL-17A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-05-20 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 62.467, 137.844, 86.524 |
| Unit cell angles | 90.00, 98.07, 90.00 |
Refinement procedure
| Resolution | 46.030 - 1.500 |
| R-factor | 0.15666 |
| Rwork | 0.154 |
| R-free | 0.18033 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2DS3 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.275 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.550 |
| High resolution limit [Å] | 1.500 | 1.500 |
| Rmerge | 0.063 | 0.388 |
| Number of reflections | 222770 | |
| <I/σ(I)> | 3.93 | |
| Completeness [%] | 96.6 | 98.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |