3VJT
Vitamin D receptor complex with a carborane compound
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-6A |
| Synchrotron site | Photon Factory |
| Beamline | BL-6A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-11-07 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 0.978 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 154.855, 42.319, 42.176 |
| Unit cell angles | 90.00, 95.59, 90.00 |
Refinement procedure
| Resolution | 40.810 - 2.000 |
| R-factor | 0.23 |
| Rwork | 0.230 |
| R-free | 0.26600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2zlc |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.100 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 18571 |
| Completeness [%] | 99.7 |
| Redundancy | 4.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 0.1M MOPS/NaOH, 0.1-0.4M sodium formate, 12-22% PEG 4000, 5% ethylene glycol , pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |