Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

3V2Z

Nitrite Bound Chlorin Substituted Myoglobin- Method 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RUH3R
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2010-05-24
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths34.285, 30.360, 64.060
Unit cell angles90.00, 104.94, 90.00
Refinement procedure
Resolution26.500 - 1.650
R-factor0.18647
Rwork0.184
R-free0.23202
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ba2
RMSD bond length0.022
RMSD bond angle2.135
Data reduction softwared*TREK
Data scaling softwared*TREK
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]26.5001.710
High resolution limit [Å]1.6501.650
Rmerge0.0380.143
Number of reflections15230
<I/σ(I)>16.85.9
Completeness [%]97.594.5
Redundancy3.213.18
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.4295ammonium sulfate, 100mM TrisHCl, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 295K

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon