Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3V2V

Nitrite Bound Chlorin Substituted Myoglobin- Method 1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RUH3R
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2010-06-21
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths34.432, 30.519, 63.579
Unit cell angles90.00, 105.23, 90.00
Refinement procedure
Resolution26.230 - 1.650
R-factor0.1932
Rwork0.192
R-free0.21760
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3ba2
RMSD bond length0.022
RMSD bond angle2.017
Data reduction softwared*TREK
Data scaling softwared*TREK
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]26.4501.710
High resolution limit [Å]1.6501.650
Rmerge0.0350.163
Number of reflections15443
<I/σ(I)>17.85.3
Completeness [%]98.795.8
Redundancy3.133.08
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.4295ammonium sulfate, 100mM TrisHCl, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 295K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon