Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-07-08 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.979 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 119.687, 45.334, 68.607 |
Unit cell angles | 90.00, 97.95, 90.00 |
Refinement procedure
Resolution | 50.000 - 1.680 |
R-factor | 0.1759 |
Rwork | 0.174 |
R-free | 0.21320 |
Structure solution method | SAD |
RMSD bond length | 0.013 |
RMSD bond angle | 1.591 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | HKL-3000 (SHELXC/D/E) |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.690 |
High resolution limit [Å] | 1.680 | 1.680 |
Rmerge | 0.039 | 0.398 |
Number of reflections | 41594 | |
<I/σ(I)> | 24.38 | 2.2 |
Completeness [%] | 99.9 | 99.4 |
Redundancy | 4.1 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 293 | 25% PEG 3350, 0.2M NaCl, 0.1M Bis-Tris, 2% Hexandiol, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |