Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E DW |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2009-05-28 |
| Detector | RIGAKU RAXIS VII |
| Wavelength(s) | 1.54178 |
| Spacegroup name | C 2 2 2 |
| Unit cell lengths | 107.538, 169.963, 53.613 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 25.060 - 2.000 |
| R-factor | 0.24374 |
| Rwork | 0.243 |
| R-free | 0.26397 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.034 |
| RMSD bond angle | 1.424 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 100.000 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 33473 |
| Completeness [%] | 99.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 300 | 20% PEG 3350, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 300.0K |