Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E DW |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2009-05-28 |
Detector | RIGAKU RAXIS VII |
Wavelength(s) | 1.54178 |
Spacegroup name | C 2 2 2 |
Unit cell lengths | 107.538, 169.963, 53.613 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 25.060 - 2.000 |
R-factor | 0.24374 |
Rwork | 0.243 |
R-free | 0.26397 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.034 |
RMSD bond angle | 1.424 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 100.000 |
High resolution limit [Å] | 2.000 |
Number of reflections | 33473 |
Completeness [%] | 99.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 300 | 20% PEG 3350, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 300.0K |