3U7A
AL-09 Y32F Y96F
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2011-02-02 |
| Detector | RIGAKU RAXIS IV++ |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 52.120, 52.120, 156.470 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 39.100 - 2.000 |
| R-factor | 0.203 |
| Rwork | 0.201 |
| R-free | 0.23200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 0.951 |
| Data reduction software | CrystalClear |
| Data scaling software | CrystalClear |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.7.1_743)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.000 | 2.080 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Number of reflections | 7792 | |
| Completeness [%] | 85.0 | 31.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 295 | 27% (w/v) polyethylene glycol 4000 and 0.15 M Li2SO4 in 0.1 M Tris HCl pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 295K |