3TMT
IrisFP, distorted chromophore
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID14-2 |
| Synchrotron site | ESRF |
| Beamline | ID14-2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-04-11 |
| Detector | ADSC QUANTUM 4 |
| Wavelength(s) | 0.9330 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 84.840, 96.510, 140.000 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 12.984 - 2.000 |
| R-factor | 0.295 |
| Rwork | 0.295 |
| R-free | 0.29500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.341 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.7.1_743)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 79.500 |
| High resolution limit [Å] | 2.000 |
| Number of reflections | 65357 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.4 | 293 | Ammonium sulfate, bicine, pH 8.4, VAPOR DIFFUSION, HANGING DROP, temperature 293K |