3TLS

The GLIC pentameric Ligand-Gated Ion Channel E19'P mutant in a locally-closed conformation (LC2 subtype)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Detector technologyCCD
DetectorADSC QUANTUM 315r
Wavelength(s)0.9919
Spacegroup nameC 1 2 1
Unit cell lengths180.272, 131.074, 158.139
Unit cell angles90.00, 101.92, 90.00
Refinement procedure
Resolution44.210 - 3.200
R-factor0.2046
Rwork0.203
R-free0.23020
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.100
Data scaling softwareSCALA
Refinement softwareBUSTER-TNT (BUSTER 2.11.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.2103.370
High resolution limit [Å]3.2003.200
Rmerge0.1210.750
Number of reflections58339
<I/σ(I)>7.42
Completeness [%]98.594.7
Redundancy3.13.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION4293pH 4, VAPOR DIFFUSION, temperature 293K

219869