mutation of sfALR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RUH3R
Temperature [K]93
Detector technologyIMAGE PLATE
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54178
Spacegroup nameC 2 2 21
Unit cell lengths50.853, 76.968, 63.289
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.640 - 1.611
R-factor0.18215
Rwork0.180
R-free0.22560
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3mbg
RMSD bond length0.026
RMSD bond angle2.337
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.660
High resolution limit [Å]1.6001.600
Rmerge0.0440.199
Number of reflections16331
<I/σ(I)>48.32557.844
Completeness [%]97.376.9
Redundancy4.74
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION62930.1 M MES, 20% PEG6000, PH 6.0, VAPOR DIFFUSION, temperature 293K

219869

PDB entries from 2024-05-15