KcsA potassium channel mutant Y82C with Cadmium bound

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Detector technologyCCD
Collection date2008-12-12
DetectorADSC QUANTUM 315
Wavelength(s)1.0
Spacegroup nameI 4
Unit cell lengths155.907, 155.907, 76.119
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.000 - 2.400
Rwork0.227
R-free0.26300
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 Overall
Low resolution limit [Å]40.000
High resolution limit [Å]2.400
Number of reflections33542
Completeness [%]93.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.529320-25% PEG400, 50mM magnesium acetate, 50mM sodium acetate, pH 5.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K