Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3ST2

Dreiklang - equilibrium state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2010-03-16
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 21 21 2
Unit cell lengths68.057, 136.213, 81.247
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.417 - 1.900
R-factor0.1607
Rwork0.158
R-free0.20570
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.279
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.6.1_353))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.920
High resolution limit [Å]1.9001.900
Rmerge0.520
Number of reflections59298
<I/σ(I)>2.23
Completeness [%]98.495.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.629315 % (w/v) PEG 3350, 0.2M KH2PO4, 3% (w/v) D-trehalose dihydrate, pH 4.6, VAPOR DIFFUSION, SITTING DROP, temperature 293K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon