3SCG
Fe(II)-HppE with R-HPP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL9-1 |
| Synchrotron site | SSRL |
| Beamline | BL9-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-11-06 |
| Detector | ADSC QUANTUM 315r |
| Spacegroup name | P 42 21 2 |
| Unit cell lengths | 111.570, 111.570, 151.334 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 3.000 |
| R-factor | 0.217 |
| Rwork | 0.217 |
| R-free | 0.25800 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1zz8 |
| RMSD bond length | 0.278 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 100.000 | 3.220 |
| High resolution limit [Å] | 3.000 | 3.000 |
| Number of reflections | 19839 | |
| <I/σ(I)> | 54.5 | 11.8 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 27.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | 2.0 M ammonium sulfate, 0.1 M Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | 2.0 M ammonium sulfate, 0.1 M Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |