3QYT
Diferric bound human serum transferrin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-06-28 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.97924 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 73.845, 90.435, 112.299 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.900 |
High resolution limit [Å] | 2.800 | 6.030 | 2.800 |
Rmerge | 0.106 | 0.047 | 0.524 |
Number of reflections | 17765 | ||
<I/σ(I)> | 9.2 | ||
Completeness [%] | 92.9 | 89 | 77.4 |
Redundancy | 5.5 | 6.4 | 2.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.4 | 271 | 0.01M HEPES, 15% PEG3000, pH 7.4, vapor diffusion, sitting drop, temperature 271K |