3QYO
Sensitivity of receptor internal motions to ligand binding affinity and kinetic off-rate
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU300 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-05-01 |
| Detector | RIGAKU SATURN 944+ |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 33.990, 45.110, 97.800 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 15.330 - 2.090 |
| R-factor | 0.1687 |
| Rwork | 0.165 |
| R-free | 0.23590 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.130 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.8.0) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 15.330 | 15.300 | 2.200 |
| High resolution limit [Å] | 2.090 | 6.600 | 2.090 |
| Number of reflections | 12094 | ||
| Completeness [%] | 99.6 | 92.2 | 99.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8 | 298 | 20 mg/mL DHFR, 20 mM imidazole, 325 mM CaCl2, 34% PEG-6000, pH 8.0, VAPOR DIFFUSION, SITTING DROP, temperature 298K |