3QH9
Human Liprin-beta2 Coiled-Coil
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-08-15 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.4938 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 29.964, 162.656, 34.387 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 81.380 - 2.010 |
R-factor | 0.2348 |
Rwork | 0.232 |
R-free | 0.29780 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.023 |
RMSD bond angle | 2.027 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 81.380 | 80.000 | 2.070 |
High resolution limit [Å] | 2.000 | 4.310 | 2.000 |
Rmerge | 0.099 | 0.071 | 0.348 |
Number of reflections | 5774 | ||
<I/σ(I)> | 12 | ||
Completeness [%] | 97.0 | 96.4 | 84.1 |
Redundancy | 10.2 | 10 | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 298 | 190 mM ammonium iodide, 23% PEG 3350, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |