3Q8D
E. coli RecO complex with SSB C-terminus
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-D |
| Synchrotron site | APS |
| Beamline | 23-ID-D |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-02-17 |
| Detector | MARMOSAIC 300 mm CCD |
| Wavelength(s) | 0.97953 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 100.199, 118.569, 145.119 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 40.000 - 2.300 |
| R-factor | 0.19678 |
| Rwork | 0.195 |
| R-free | 0.23406 |
| Structure solution method | SAD |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.005 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHENIX |
| Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.340 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.064 | 0.653 |
| Number of reflections | 38294 | |
| <I/σ(I)> | 1.8 | |
| Completeness [%] | 98.4 | 87.2 |
| Redundancy | 3.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 298 | pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 298 | pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K |