3PJK
Urate oxidase under 1.0 MPa / 10 bars pressure of xenon
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM14 |
Synchrotron site | ESRF |
Beamline | BM14 |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 2007-11-15 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 0.976 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 80.117, 96.183, 105.463 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.450 - 1.701 |
R-factor | 0.16801 |
Rwork | 0.167 |
R-free | 0.19171 |
Structure solution method | RIGID BODY |
Starting model (for MR) | 2iba |
RMSD bond length | 0.012 |
RMSD bond angle | 1.481 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.760 |
High resolution limit [Å] | 1.700 | 1.700 |
Number of reflections | 43762 | |
<I/σ(I)> | 31.8 | 3.5 |
Completeness [%] | 97.1 | |
Redundancy | 4.9 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH | 8.5 | 298 | 10-15 MG/ML URATE OXIDASE, 8-AZAXANTHINE 0.2 MG/ML, TRIS 50 MM, PEG 8000 5-8%, NACL 0-50 MM, pH 8.5, BATCH, temperature 298K |