3OU6
DhpI-SAM complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2008-07-26 |
| Detector | MAR scanner 300 mm plate |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 166.428, 166.428, 168.076 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 25.000 - 2.300 |
| R-factor | 0.19259 |
| Rwork | 0.190 |
| R-free | 0.23728 |
| Structure solution method | SAD |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.429 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | REFMAC (5.5.0056) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.470 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.117 | 0.459 |
| Number of reflections | 60586 | |
| <I/σ(I)> | 39.8 | 7.7 |
| Completeness [%] | 99.7 | 100 |
| Redundancy | 18.3 | 17.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 273 | 1.6 M Ammonium sulphate, 100 mM Tris-HCl pH=8.0, VAPOR DIFFUSION, HANGING DROP, temperature 273K |