Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3NEO

Wild type human transthyretin (TTR) complexed with GC-24 (TTRwt:GC-24)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsLNLS BEAMLINE W01B-MX2
Synchrotron siteLNLS
BeamlineW01B-MX2
Temperature [K]100
Detector technologyCCD
Collection date2009-03-15
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.4586
Spacegroup nameP 21 21 2
Unit cell lengths42.770, 84.910, 64.440
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.910 - 2.000
R-factor0.185
Rwork0.183
R-free0.22000
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.014
RMSD bond angle1.568
Data reduction softwareMOSFLM
Data scaling softwareSCALA (3.3.16)
Phasing softwarePHASER
Refinement softwareREFMAC
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]64.44025.9102.110
High resolution limit [Å]2.0006.3202.000
Rmerge0.0480.439
Total number of observations354214565
Number of reflections16052
<I/σ(I)>13.19.81.8
Completeness [%]97.796.795.6
Redundancy6.46.16.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52930.2 M CaCl2, 0.1 M HEPES pH 7.5, 28% PEG 400, vapor diffusion, hanging drop, temperature 293K

219869