3NCP
GlnK2 from Archaeoglobus fulgidus
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE X12 |
Synchrotron site | EMBL/DESY, HAMBURG |
Beamline | X12 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.00 |
Spacegroup name | P 3 |
Unit cell lengths | 91.000, 91.000, 64.432 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 37.170 - 2.350 |
R-factor | 0.2018 |
Rwork | 0.201 |
R-free | 0.22000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2gnk |
RMSD bond length | 0.010 |
RMSD bond angle | 1.360 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | BUSTER (2.9.4) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.500 | 2.440 |
High resolution limit [Å] | 2.350 | 2.350 |
Rmerge | 0.061 | 0.366 |
Number of reflections | 24887 | |
<I/σ(I)> | 6.38 | 2.91 |
Completeness [%] | 99.8 | 99.5 |
Redundancy | 2.45 | 2.49 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8 | 293 | PEG 4000, Na Acetate, pH 8.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |