Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL7-1 |
| Synchrotron site | SSRL |
| Beamline | BL7-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2007-03-31 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.978 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 70.840, 95.229, 42.585 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 27.230 - 1.500 |
| R-factor | 0.1724 |
| Rwork | 0.171 |
| R-free | 0.19638 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | PDB ENTRY oxidized H88Q structure |
| RMSD bond length | 0.019 |
| RMSD bond angle | 2.124 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 27.230 | 1.539 |
| High resolution limit [Å] | 1.500 | 1.500 |
| Number of reflections | 37223 | |
| Completeness [%] | 79.3 | 71.01 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 1.7-2.2 M ammonium sulfate, 0.26-0.32 M NaCl, and 0.1 M sodium cacodylate, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |