3N2G
TUBULIN-NSC 613863: RB3 Stathmin-like domain complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-11-10 |
Detector | ADSC |
Spacegroup name | P 65 |
Unit cell lengths | 328.553, 328.553, 54.745 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.000 - 4.000 |
R-factor | 0.21094 |
Rwork | 0.209 |
R-free | 0.24078 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1sa0 |
RMSD bond length | 0.017 |
RMSD bond angle | 1.782 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | AMoRE |
Refinement software | REFMAC (5.1.24) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 4.100 |
High resolution limit [Å] | 4.000 | 4.000 |
Number of reflections | 29143 | |
<I/σ(I)> | 22 | 2.4 |
Completeness [%] | 98.2 | 94.2 |
Redundancy | 4 | 2.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7 | PEG, PIPES BUFFER, PH 7.0, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 277K |