3MT5
Crystal Structure of the Human BK Gating Apparatus
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-12-12 |
| Wavelength(s) | 0.9792 |
| Spacegroup name | P 63 2 2 |
| Unit cell lengths | 144.518, 144.518, 182.195 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 47.500 - 3.000 |
| R-factor | 0.248 |
| Rwork | 0.246 |
| R-free | 0.27800 |
| Structure solution method | MAD |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.215 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | SOLVE (2.13) |
| Refinement software | REFMAC |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 3.110 |
| High resolution limit [Å] | 3.000 | 6.460 | 3.000 |
| Rmerge | 0.089 | 0.032 | 0.738 |
| Number of reflections | 23149 | ||
| <I/σ(I)> | 9.4 | ||
| Completeness [%] | 99.9 | 99.8 | 99.9 |
| Redundancy | 5.8 | 5.2 | 5.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 293 | PEG 4000, pH 4.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 293 | PEG 4000, pH 4.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 293 | PEG 4000, pH 4.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4.8 | 293 | PEG 4000, pH 4.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |