Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-4 |
Synchrotron site | ESRF |
Beamline | ID14-4 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-02-02 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.9393 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 94.910, 69.260, 147.210 |
Unit cell angles | 90.00, 107.00, 90.00 |
Refinement procedure
Resolution | 20.110 - 2.040 |
R-factor | 0.18815 |
Rwork | 0.186 |
R-free | 0.22283 |
Structure solution method | MAD |
RMSD bond length | 0.015 |
RMSD bond angle | 1.806 |
Data reduction software | HKL-2000 |
Data scaling software | XDS |
Phasing software | SHARP |
Refinement software | REFMAC (5.6.0046) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.160 |
High resolution limit [Å] | 2.000 | 2.000 |
<I/σ(I)> | 0.074 | 2.3 |
Completeness [%] | 95.3 | 79.4 |
Redundancy | 2.5 | 2.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 291 | 20% PEG 4000, 100 mM Na-citrate, 0.2 M NaCl, 5% (v/v) 2-propanol, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 291.0K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 291 | 20% PEG 4000, 100 mM Na-citrate, 0.2 M NaCl, 5% (v/v) 2-propanol, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 291.0K |