Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3MHP

FNR-recruitment to the thylakoid

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsBRUKER AXS MICROSTAR
Temperature [K]100
Detector technologyCCD
Collection date2009-11-01
DetectorBruker Platinum 135
Wavelength(s)1.5418
Spacegroup nameP 1
Unit cell lengths47.463, 48.824, 71.349
Unit cell angles106.56, 97.01, 91.77
Refinement procedure
Resolution14.980 - 1.700
R-factor0.181
Rwork0.181
R-free0.20600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1qg0
RMSD bond length0.005
RMSD bond angle1.300
Data reduction softwarePROTEUM PLUS (PLUS)
Data scaling softwarePROTEUM PLUS (PLUS)
Phasing softwarePHASER
Refinement softwareCNS (1.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]60.0001.800
High resolution limit [Å]1.7001.700
Rmerge0.0350.236
Number of reflections66902
<I/σ(I)>23.6
Completeness [%]99.999.5
Redundancy10.93.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6293200 mM Ammoniumcitrate 20 % PEG 3350 crystal growth - 3 month, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon