Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3M8W

Phosphopentomutase from Bacillus cereus

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-G
Synchrotron siteAPS
Beamline21-ID-G
Temperature [K]100
Detector technologyCCD
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.979
Spacegroup nameP 1 21 1
Unit cell lengths91.238, 76.552, 106.561
Unit cell angles90.00, 108.89, 90.00
Refinement procedure
Resolution20.000 - 1.850
R-factor0.1582
Rwork0.157
R-free0.18570
RMSD bond length0.008
RMSD bond angle1.080
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.7001.920
High resolution limit [Å]1.8501.850
Number of reflections116902
<I/σ(I)>13.33
Completeness [%]98.699.1
Redundancy3.12.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon