3LQM
Structure of the IL-10R2 Common Chain
Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-10-06 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1.0 |
Spacegroup name | P 6 |
Unit cell lengths | 124.839, 124.839, 84.223 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 50.000 - 2.140 |
R-factor | 0.21 |
Rwork | 0.210 |
R-free | 0.23900 |
Structure solution method | MAD |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | SOLVE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.140 |
Number of reflections | 40491 |
<I/σ(I)> | 50 |
Completeness [%] | 97.5 |
Redundancy | 11 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |