3LJ1
IRE1 complexed with Cdk1/2 Inhibitor III
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Detector technology | CCD |
| Collection date | 2008-11-07 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 32 1 2 |
| Unit cell lengths | 125.550, 125.550, 174.390 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 51.260 - 3.330 |
| R-factor | 0.264 |
| Rwork | 0.263 |
| R-free | 0.28400 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2rio |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.507 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA (3.3.9) |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.5.0072) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 51.264 |
| High resolution limit [Å] | 3.330 |
| Number of reflections | 22895 |
| Completeness [%] | 98.4 |
| Redundancy | 4.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | hanging drop | 298 | hanging drop, temperature 298K |