3L1T
E. coli NrfA sulfite ocmplex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-2 |
Synchrotron site | ESRF |
Beamline | ID14-2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2005-12-03 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.933 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 90.520, 82.234, 142.172 |
Unit cell angles | 90.00, 101.08, 90.00 |
Refinement procedure
Resolution | 50.360 - 2.300 |
R-factor | 0.17971 |
Rwork | 0.177 |
R-free | 0.23809 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2rdz |
RMSD bond length | 0.010 |
RMSD bond angle | 1.233 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | REFMAC (5.5.0066) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 60.900 | 2.420 |
High resolution limit [Å] | 2.300 | 2.300 |
Number of reflections | 91009 | |
<I/σ(I)> | 7.8 | 1.8 |
Completeness [%] | 99.8 | 99.6 |
Redundancy | 3.8 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | 100mM HEPES, 20% PEG 10K, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |