3KRM
Imp1 kh34
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X29A |
| Synchrotron site | NSLS |
| Beamline | X29A |
| Detector technology | CCD |
| Collection date | 2008-12-04 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 65 |
| Unit cell lengths | 103.530, 103.530, 131.600 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 50.000 - 2.750 |
| R-factor | 0.1999 |
| Rwork | 0.198 |
| R-free | 0.23860 |
| Structure solution method | MIR |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.227 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 53.000 | 2.900 |
| High resolution limit [Å] | 2.750 | 2.750 |
| Rmerge | 0.064 | 0.806 |
| Number of reflections | 20824 | |
| <I/σ(I)> | 2.9 | |
| Completeness [%] | 99.9 | 100 |
| Redundancy | 9.7 | 9.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.8 | 295 | 1.65M Ammonium Citrate, 100mM Tris, pH 7.8, VAPOR DIFFUSION, SITTING DROP, temperature 295K |