3KLY
Pentameric formate channel
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X25 |
| Synchrotron site | NSLS |
| Beamline | X25 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2008-10-31 |
| Detector | ADSC |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 100.795, 101.030, 192.629 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 33.460 - 2.100 |
| R-factor | 0.18 |
| Rwork | 0.179 |
| R-free | 0.20900 |
| Structure solution method | SIRAS |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.995 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((phenix.refine: 1.5_2)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.100 |
| Number of reflections | 102406 |
| <I/σ(I)> | 12.43 |
| Redundancy | 7.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 291 | 0.2M TRIS, PH 7.5, 28% (W/V) PEG 550MME, 100MM NACL, 20MM SODIUM FORMATE, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 291K |