3JZH
EED-H3K79me3
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E+ DW |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2009-08-01 |
| Detector | RIGAKU |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 57.823, 85.285, 91.202 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 62.290 - 2.050 |
| R-factor | 0.16307 |
| Rwork | 0.160 |
| R-free | 0.21762 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.023 |
| RMSD bond angle | 1.914 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.5.0072) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 62.300 |
| High resolution limit [Å] | 2.050 |
| Rmerge | 0.178 |
| Number of reflections | 29058 |
| <I/σ(I)> | 4.8 |
| Completeness [%] | 100.0 |
| Redundancy | 6.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 300 | 3.5M NaF, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 300K |