3IU4

anti NeuGcGM3 ganglioside chimeric antibody chP3

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]200
Detector technologyCCD
Collection date2007-10-08
DetectorADSC Q210
Spacegroup nameI 4 2 2
Unit cell lengths153.450, 153.450, 111.480
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.570 - 1.750
R-factor0.196
Rwork0.194
R-free0.23400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)PDB 1CEL
RMSD bond length0.027
RMSD bond angle2.247
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0066)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]55.7001.790
High resolution limit [Å]1.7501.750
Rmerge0.0660.515
Number of reflections63026
<I/σ(I)>19.24.2
Completeness [%]99.414.5
Redundancy8.87.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
16.5293Final data were collected on a crystal obtained from crystallization conditions containing 30% polyethylene glycol (PEG) 10K, 0.1 M cacodylate pH 6.5 and 0.2 M ammonium sulfate, which had grown to a size of 0.2x0.1x0.1 mm3 over 7.5 months. 15% glycerol was used as a cryo-protectant, VAPOR DIFFUSION, HANGING DROP, temperature 293K

219869

PDB entries from 2024-05-15