3HMB
Mutant endolysin from Bacillus subtilis
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E SUPERBRIGHT |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2005-02-07 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.54 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 62.670, 152.760, 188.880 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.000 - 2.700 |
Rwork | 0.213 |
R-free | 0.24910 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3HMA |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.850 |
High resolution limit [Å] | 2.700 | 2.700 |
Rmerge | 0.200 | |
Number of reflections | 25390 | |
<I/σ(I)> | 10 | |
Completeness [%] | 99.9 | 100 |
Redundancy | 6.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |