Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3GW3

human UROD mutant K297N

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU200
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2008-08-18
DetectorRIGAKU RAXIS IV
Wavelength(s)1.5418
Spacegroup nameP 31 2 1
Unit cell lengths103.073, 103.073, 72.066
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution33.410 - 1.700
R-factor0.185
Rwork0.184
R-free0.23800
RMSD bond length0.016
RMSD bond angle1.533
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Refinement softwareREFMAC
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]40.00040.0001.760
High resolution limit [Å]1.7003.6601.700
Rmerge0.0760.0590.476
Number of reflections48712
<I/σ(I)>17.191
Completeness [%]99.399.496.9
Redundancy5.35.73.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1hanging drophanging drop

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon