3FZU
IgG1 Fab characterized by H/D exchange
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 31-ID |
Synchrotron site | APS |
Beamline | 31-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-02-01 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1.000 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 243.051, 61.938, 100.846 |
Unit cell angles | 90.00, 113.94, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.500 |
R-factor | 0.21301 |
Rwork | 0.210 |
R-free | 0.26107 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.029 |
RMSD bond angle | 2.743 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.500 |
Rmerge | 0.089 |
Number of reflections | 42711 |
<I/σ(I)> | 31.7 |
Completeness [%] | 93.9 |
Redundancy | 4.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | 38% PEG 400, 200 mM sodium chloride, 100 mM Tris, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |