3FR1
NFLVHS segment from Islet Amyloid Polypeptide (IAPP or Amylin)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-04-18 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9792 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 11.480, 9.552, 38.582 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 11.000 - 1.850 |
R-factor | 0.196 |
Rwork | 0.192 |
R-free | 0.23200 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.608 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 90.000 | 90.000 | 1.990 |
High resolution limit [Å] | 1.850 | 3.160 | 1.850 |
Rmerge | 0.183 | 0.138 | 0.419 |
Number of reflections | 434 | ||
Completeness [%] | 93.9 | 97.3 | 82.9 |
Redundancy | 5.4 | 4.6 | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 0.18M MgCl2, 0.09M HEPES pH 7.5, 27% isopropanol, and 10% glycerol, vapor diffusion, hanging drop, temperature 298K |