3DGJ
NNFGAIL segment from Islet Amyloid Polypeptide (IAPP or amylin)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID13 |
Synchrotron site | ESRF |
Beamline | ID13 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-10-09 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1.0 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 26.190, 4.897, 31.380 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.110 - 1.800 |
R-factor | 0.166 |
Rwork | 0.160 |
R-free | 0.21700 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.150 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.110 | 1.900 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.158 | 0.294 |
Number of reflections | 481 | 62 |
<I/σ(I)> | 8.98 | 3.8 |
Completeness [%] | 98.8 | 98.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 20% ethylene glycol, no buffer, VAPOR DIFFUSION, HANGING DROP, temperature 293K |