Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH2R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 1997-06-15 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 77.840, 89.930, 69.070 |
Unit cell angles | 90.00, 97.70, 90.00 |
Refinement procedure
Resolution | 14.920 - 1.900 |
R-factor | 0.179 |
Rwork | 0.176 |
R-free | 0.23300 |
Starting model (for MR) | 5gss |
RMSD bond length | 0.016 |
RMSD bond angle | 1.543 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | X-PLOR |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 15.000 | 1.970 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 0.043 | 0.235 |
Number of reflections | 33345 | |
<I/σ(I)> | 19 | 3.9 |
Completeness [%] | 89.9 | 87.9 |
Redundancy | 2.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |