3CNN
GTP-bound structure of TM YlqF
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 6C1 |
Synchrotron site | PAL/PLS |
Beamline | 6C1 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 1.23985 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 35.264, 75.295, 105.106 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.060 - 2.300 |
R-factor | 0.235 |
Rwork | 0.229 |
R-free | 0.28300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1puj |
RMSD bond length | 0.011 |
RMSD bond angle | 1.373 |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Number of reflections | 12903 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 297 | 100mM HEPES (pH 7.5), 5% (v/v) isopropanol, 20% (w/v) polyethylene glycol 4000, VAPOR DIFFUSION, HANGING DROP, temperature 297K |