3BY2
Norwalk P polypeptide (228-523)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH3R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | I 21 21 21 |
Unit cell lengths | 82.799, 83.771, 102.229 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.600 |
Rwork | 0.212 |
R-free | 0.27080 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ihm |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.600 |
Number of reflections | 8083 |
Redundancy | 1.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |