3BN4
Carboxysome Subunit, CcmK1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-11-08 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.97944 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 120.900, 69.770, 78.010 |
Unit cell angles | 90.00, 94.61, 90.00 |
Refinement procedure
Resolution | 60.300 - 2.000 |
R-factor | 0.206 |
Rwork | 0.203 |
R-free | 0.25000 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.366 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 90.000 | 90.000 | 2.070 |
High resolution limit [Å] | 2.000 | 4.310 | 2.000 |
Rmerge | 0.128 | 0.102 | 0.515 |
Number of reflections | 43130 | ||
<I/σ(I)> | 8.3 | ||
Completeness [%] | 98.8 | 97.6 | 97.8 |
Redundancy | 5.3 | 5.8 | 4.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 298 | 0.1M MES, 15% MPD, 0.1M lithium sulfate, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K |